Boiler Feed Pump Turbine & Fluid Drive Lube Oil Filtration Systems
.jpg)
Boiler Feed Pump Turbine Lube Oil
Models KL30H, KL10H, KL5H and KL1 TURBO-TOC® Turbine Oil Conditioners
BFP turbines typically have water ingression problems with the turbine lube oil. The KL Series(depending on lube oil size reservoir) is capable of handling large water ingression problems found with BFP turbines. The smaller KL Series can be sized to your specific lube BFP turbine oil reservoir.
Sizing Info
Reservoirs to 240 gallons - KL1
241 to 600 gallons - KL5
601 to 1,200 gallons - KL10H
1,201 to 3,600 gallons - KL30H
.jpg)
Model KL1
Lube Oil Conditioner for Fluid Drive Lube Oil
Fan fluid drives and boiler feed pump fluid drives are critical power plant equipment, so oil cleanliness is essential for power transmission, lubrication, and dissipating of heat. Most Fluid drives have been in operation for several years on continuous service or stop/start service and the oil quality should be considered to maintain a dependable working fluid drive. the most common brans of variable speed Fluid Drives used in power plants are American Blower, American Standard, and Howden Buffalo. One of the most common causes of an unscheduled shutdown of a fluid drive is bearing and oil pump wear due to poor oil quality. the Kaydon Model KL1 is designed to remove solid contamination and water from the lube oil used with Fluid Drives. The KL1 is installed independently of the Fluid Drive, so it will not cause any problems, as in-line filters do, with oil pressure and oil flow. The KL1 operates continually with its own pump/motor assembly at a flow of 1 gpm continuously removing solid contamination and water from the oil in the Fluid Drive.
- Solid contamination and water removal in one very compact design (22"L x 12"W x 32"H)
- 1 gpm continuous process rate for fast reservoir turn over and generous reserve for emergencies
- Suitable for reservoir capacities to 240 gallons
- Extremely compact design mounts directly on or adjacent to reservoir
- Removal of particulate smaller than bearing clearances with absolute rated filter elements
- 80% single pass water removal
- Low maintenance, operator not required
- Light weight, less than 65 pounds dry
- Very low operating cost
- Simple installation
.jpg)
.jpg)
.gif)